BATTERY MONITORING IC FOR 3-SERIAL TO 5-SERIAL CELL PACK S-8225B Series

The S-8225B Series includes a voltage detection circuit with high accuracy and a delay circuit, and can monitor the status of 3-serial to 5-serial cell lithium-ion rechargeable battery in single use. By switching the voltage level which is applied to the SEL1 pin and SEL2 pin, users are able to use the S-8225B Series for 3-serial to 5-serial cell pack.

  • High-accuracy voltage detection for each cell
    Overcharge detection voltage n (n = 1 to 5) : 3.5 V to 4.4 V (50 mV step), Accuracy ±20 mV (Ta = +25°C), ±30 mV (Ta = 0°C to +60°C)
    Overcharge release voltage n (n = 1 to 5) : 3.3 V to 4.4 V*1 , Accuracy ±50 mV
    Overdischarge detection voltage n (n = 1 to 5) : 2.2 V to 3.2 V (100 mV step) , Accuracy ±80 mV
    Overdischarge release voltage n (n = 1 to 5) : 2.2 V to 3.4 V*2 , Accuracy ±100 mV
  • Overcharge detection delay time and overdischarge detection delay time can be set by external capacitor.
  • Switchable between 3-serial to 5-serial cell by using the SEL1 pin and the SEL2 pin
  • The CO pin and the DO pin are controlled by the CTLC pin and the CTLD pin, respectively.
  • Output voltage of the CO pin and the DO pin is limited to 12 V max.
  • Output logic is selectable. : Active "H", active "L"
  • Withstand voltage element : Absolute maximum rating: 28 V
  • Wide operating voltage range : 4 V to 26 V
  • Wide operating temperature range : Ta = -40°C to +85°C
  • Low current consumption
    During operation (V1 = V2 = V3 = V4 = V5 = 3.4 V) : 20 µA max. (Ta = +25°C)
    During power-down (V1 = V2 = V3 = V4 = V5 = 1.6 V) : 3.0 µA max. (Ta = +25°C)
  • Lead-free (Sn 100%), halogen-free
  • Package : 16-Pin TSSOP

*1. Overcharge hysteresis voltage n (n = 1 to 5) is selectable in 0 V, or in 0.1 V to 0.4 V in 50 mV step.
(Overcharge hysteresis voltage = Overcharge detection voltage - Overcharge release voltage)
*2. Overdischarge hysteresis voltage n (n = 1 to 5) is selectable in 0 V, or in 0.2 V to 0.7 V in 100 mV step.
(Overdischarge hysteresis voltage = Overdischarge release voltage - Overdischarge detection voltage)



  • Rechargeable lithium-ion battery pack